When the sensor is correctly adjusted,
tighten the two hex screws on the sides of
the sensor.
Check and tighten if necessary the locking
screws for the anemometer and wind
direction indicator.
FIG. 11
MAINTENANCE
Clean the rain gauge at regular intervals (every
three months, depending on how much it rains).
1. Release the precipitation funnel by
turning it as shown in the gure.
FIG. 12
2. Carefully remove any debris from the
precipitation sensor.
3. Remove debris from the precipitation
funnel and its outlet.
4. Clean the outlet.
5. Replace the precipitation funnel.
NOTE:
Never apply any oil on the precipitation
sensor.
The wireless sensor must be placed no
more than 100 metres from the weather
station (free eld without obstruction).
Obstructions will aect the range for
data transmission. The distance should
be as short as possible.