EasyManua.ls Logo

Masseuse Ultimate Chiro - Troubleshooting: Massage Chair Not Working - Power Issues; Power Supply and Switch Box Problems; Fuse Burn Troubleshooting Steps

Masseuse Ultimate Chiro
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IV. Troubleshoot of the chair—— Massage chair does not work
Failure Analysis of The massage chair does not work
1. External power supply and power swith box problem
2. Fuse burned
3. The power board without DC5V power output
4. Main board problem
5. Remote controller problem
Specific exclusion Fault Analysis
I. First, the external power supply and power switch box problem
Troubleshooting:
1. As shown Figure 2, please check if the power filter outlet loose? Is there AC220V power output from the flapper home?
Check and excluded.
2. Filter, is power switch itself good? I did plug the power cord plugged in correctly? Check and excluded.
II. Second, the fuse burned Troubleshooting:
1. As shown in Figure 2, a power switch with a 4A fuse or in Figure 4 the power board with 6A fuse if it fails to boot after being burned,
So burn this two fuses There are several possible:
shown in Figure 7, "471" varistors short-circuit breakdown, removal or replacement can be solved this problem.
power switching power supply circuit board DC5V short-circuit breakdown some components, such as "4007" diode, "4.7UF / 400V"
capacitor "274" integration, exclusion or replacement can be;
Figure 6 Power board
471 Piezoresistor