87
2. Electric System
problem
Ignition time is late or early
Spark is weak or no spark
Adjust ignition time
Check from plug to magneto
3. Air pass problem Leakage on engine
Air filter is dirty
Cylinder, piston, ring worn out
Leakages on connecting face
Block in exhaust pipe
Leakage on Air inlet pipe
Repair
Clean or change filter
Repair or change
Repair or change
Dredge
Repair or change
4. Engine cooling
system
Block in water channel or radiator
Air in Cooling system or coolant is
not enough
Water pump problem
Unsuitable coolant
Constant temperature unit problem
Fault on motor of fan or switch of
heat-sensor
Clear
Release air, refill
coolant
Change
Change
Change
Change
5. Miscellaneous Carbon accumulated on top of
piston
Too many or less lube
Unsuitable lube used
Clear
Drain or Refill
Change
Noise from Noise on air valve Gap on valve is too big Adjust