Problem Possible Cause Corrective Action
The connection between the regulator
and LP tank are not in good condition.
The LP tank valve and regulator
control valve are not open.
The LP tank is empty.
Push button of safety valve was not
pushed down.
The burner does
not light up.
Troubleshooting
Check and make sure the regulator coupling nut is tightened to
the LP tank valve.
The regulator control valve and LP tank valve is open during normal
operation. The regulator control valve is opened in clockwise
direction and the LP tank valve is opened in counter-clockwise direction.
Check and make sure the LP tank is filled with fuel.
Press and fully hold down push button of safety valve after the lighted
match is placed on the burner.
The burner does
not stay lit.
The push button on safety valve was
not fully pushed down for at least
10 seconds.
Timer is not activated.
The thermocouple is not in direct flame
path of burner.
High wind condition.
Timer has completed its cycle.
Fully hold down the push button on safety valve at least 10 seconds
and then release.
Fully turn the timer control knob clockwise.
Ensure the thermocouple is assembled in right position and the nut is
tightened on the thermocouple. (See Assembly Instructions - step 2 for
detail). Make sure the flame has full contact with the thermocouple.
If wind blows out flame, gas supply will be cut o. Move out of wind
and restart.
Each cycle of timer is 15 minutes, after 15 minutes, the burner will go
o automatically. Please re-set the timer.
The oil is not
reaching desired
temperature.
The food is not fully defrosted.
The regulator control valve is not
fully opened.
Overfilled Protection Device (OPD) on
tank has been tripped.
Do not attempt to fry a frozen or partially frozen turkey or food.
Ensure the turkey or food is completely thawed prior to proceeding.
Fully open the regulator control valve. The regulator control valve is
opened in clockwise direction and the LP tank valve is opened in
counter-clockwise direction.
Overfilled Protection Device (OPD) has been activated. To reset, turn o
regulator control valve and LP tank valve. Disconnect the regulator from
the LP tank and wait one minute. Reconnect the regulator control valve
to the LP tank valve and slowly open the LP tank valve until it is fully open.
Product no. 085-3230-2 (TF2115708-MC-00) |