33DO NOT DIVE.
MODEL SPECIFICATIONS
Model Listing
Number
Spa
Dimensions
(in./cm)
Electrical
Requirements
1
Seating
Capacity
2
Water
Capacity
3
(gallons/m)
Dry
Weight
4
(lbs./kilos)
Full
Weight
3,4
(lbs./kilos)
Therapy
Pumps
Control
System
INT EVO
COMPACT
1490 78"x 66"x 32"
199 x 168 x 82"
*240V, 16A
240V, 32A
2x 240V, 16A
3 170 / 0.64 600 / 272 2575 / 1168 1 BP6013G
2KW
SIGNATURE 4
1510 78"x 78"x 32"
199 x 199 x 82
*240V, 16A
240V, 32A
2x 240V, 16A
4 240 / 0.91 720 / 327 3465 / 1572 1 BP6013G
2KW
HURRICANE 1520 84"x 84"x 36"
214 x 214 x 92
*240V, 32A
2x 240V, 16A
3x 240V, 16A
5 300 / 1.14 840 / 381 4270 / 1937 1 MS6013XE
TORNADO
LEGEND
1530 84"x 84"x 36"
214 x 214 x 92
*240V, 32A
2x 240V, 16A
3x 240V, 16A
5 305 / 1.15 900 / 408 4370 / 1982 2 MS6013XE
TORNADO
ALL SEATER
1540 84"x 84"x 36"
214 x 214 x 92
*240V, 32A
2x 240V, 16A
3x 240V, 16A
7 325 / 1.23 860 / 390 4870 / 2209 2 MS6013XE
SIGNATURE AS 1550 94"x 94"x 36"
239 x 239 x 92
*240V, 32A
2x 240V, 16A
3x 240V, 16A
7 380 / 1.44 1020 / 463 5485 / 2488 2 MS6013XE
SIGNATURE 1 1560 94"x 94"x 36"
239 x 239 x 92
*240V, 32A
2x 240V, 16A
3x 240V, 16A
6 370 / 1.40 1040 / 472 5240 / 2377 2 MS6013XE
SIGNATURE DL 1710 94"x 94"x 36"
239 x 239 x 92
*240V, 32A
2x 240V, 16A
3x 240V, 16A
5 375 / 1.42 970 / 440 5025 / 2279 2 MS6013XE
1
See Electrical Requirements section for further details.
2
Total bather capacity in spa. The number of bathers in spa should never exceed indicated seating capacity. Depending on
spa size, water level and bather displacement; full seating capacity may not be achievable. Do not allow additional bath-
ers to enter if bather displacement results in water levels overflowing or reaching the spa controls (air controls, diverters,
spa topside control and etc.) as this will result in water leaking out of the spa shell and potentially in to the equipment
area.
3
Full weight based on dry weight of spa, max seating capacity of spa, assumed average weight per person of 185 pounds
and estimated water weight of 8.34 pounds per gallon. Rounded up in increments of 5.
4
Manufacturing tolerances along with other factors can result in variance in actual spa weight. If weight is a critical figure
necessary for delivery, or final installation, we suggest a minimum of 15% be added to the listed weight when planning
delivery or installation.
* Default Minimum Electrical Requirement as Configured from Manufacturing. See Electrical Requirements Section for
Electrical Hook-Up by Control System.