Integrity Bath
Model MB-80R
Operation Manual
Important Safety Instructions
Read & Follow All Instructions Thoroughly
Question and Answer IconNeed help?

Do you have a question about the Mastercare MB-80R and is the answer not in the manual?

Summary

Important Safety Instructions

Operator Training Requirement

Operator must be trained by a qualified trainer or complete online video training before use.

Filling the Reservoir Operation

Instructions for filling the reservoir, adjusting temperature, and operating fill valves.

Transferring and Securing the Individual

Placing Individual into Transfer Chair

Steps for positioning the transporter, locking brakes, and transferring the patient.

Securing the Individual

Guidelines for using security belts for upper and lower body support.

Weighing and Opening the Tub Door

Individual Weighing Procedure

Key steps for obtaining accurate weights using the transporter scale.

Opening the Tub Door Mechanism

Instructions on how to open the tub door using the cam arm and release knob.

BathAire System Operation

Activating and Adjusting BathAire

How to turn on BathAire, adjust air flow, and utilize aromatherapy features.

Tub Transfer and Filling

Transferring into Tub and Closing Door

Procedure for transferring the individual into the tub and securely closing the door.

Filling the Tub with Water

Instructions for filling the tub with water to the desired level.

Bath Procedures and End of Cycle

Shampoo and Body Wash Process

Steps for shampooing and washing the individual during the bath.

End of Bath Cycle Operations

Instructions for draining the tub and preparing for individual removal.

Cleaning and Maintenance Procedures

Moving Individual Out and Cleaning

Steps for moving the individual out, cleaning surfaces, and disinfecting.

Rinsing and BathAire Purge Cycle

Procedures for rinsing after cleaning and the BathAire purge cycle.

General Considerations and Warnings

Storage and Wall Chart Recommendations

Notes on storage areas, key security, and wall chart placement.

BathAire Variable System Control

Activating BathAire and Aromatherapy

Steps for preparing and activating the BathAire system and aromatherapy.

BathAire System Functionality Details

Details on air volume, wave mode, purge cycle, and internal timer.

Bath Oil and Shampoo Dispensing

Dispensing Operation and Priming

Instructions for using the bath oil and shampoo dispensing system and priming.

Replacing Solution Jugs

Procedure for replacing one-liter jugs and priming the dispensing system.

Disinfectant Dispensing System

Connecting and Operating Disinfectant Dispenser

Instructions for connecting and operating the disinfectant dispensing system.

Transfer Chair Pads and Belting

Applying Transfer Chair Pads

How to apply comfort pads to the transporter seat using suction cups.

Belting Instructions and Variations

Guidelines for securing security belts and available belt variations.

Overview

The MasterCare Integrity Bath Model MB-80R is a patient bathing system designed for safe and comfortable transfers and bathing. It integrates several features to enhance patient care and operator convenience, including a reservoir for water, a shower wand, disinfectant wand, BathAire system for air and heat, and a transfer chair.

Function Description:

The Integrity Bath system facilitates the bathing of individuals, particularly those with mobility limitations, by providing a secure and comfortable environment. The process involves transferring the individual into a specialized transfer chair, securing them, and then moving the chair into the tub. The tub is filled with temperature-controlled water, and the BathAire system can be activated for a therapeutic air and heat experience, with optional aromatherapy. After bathing, the tub is drained, and the individual is transferred out. The system also includes features for cleaning and disinfecting the tub and chair.

Important Technical Specifications:

  • Water Temperature Control: The system allows for precise control of bath water temperature, with a recommended range of 96°F to 105°F. A mixing valve is preset to prevent mixed water from exceeding 110°F, and a temperature thermometer on the reservoir monitors the fill temperature.
  • Reservoir Capacity: The reservoir automatically fills and shuts off when full, ensuring an adequate water supply for bathing.
  • BathAire System: This system provides variable speed air and heat for a therapeutic experience. It includes an ON/OFF touch pad, plus (+) and minus (-) sections to adjust airflow, and a "Wave" mode for long or short cycle effects. It also has an internal timer that shuts off the blower after 20 minutes and a purge cycle that runs for 1 minute, 20 minutes after the blower is turned off, to dry aerators.
  • Aromatherapy: The system supports aromatherapy through a cartridge holder, allowing for the use of selected scent cartridges.
  • Disinfectant Dispensing System: A dedicated wand and valve allow for the application of disinfectant/cleaner to all surfaces of the tub and chair.
  • Shampoo/Body Wash Dispensing System: The system includes a dispensing portal for MasterCare's specially formulated shampoo and body wash, with preset economic portions.
  • Electronic Scale (Optional): Some transporters may include an electronic scale for weighing individuals. It features ON/ZERO, LB/KG, and RECALL buttons. The battery life indicator is displayed as the last set of numbers after pressing ON/ZERO.
  • Door Mechanism: The tub features a secure door with a latch release knob and a cam arm for locking.
  • Transfer Chair: The transfer chair includes security belts for upper and lower body restraint and caster brakes for stability during transfers. Optional comfort pads with suction cups can be used for enhanced patient comfort.

Usage Features:

  • Patient Transfer: The transfer chair is designed for easy transfer of individuals, with a requirement for the chair to be in a full upright position during all transfers. Caster brakes must be locked during transfers.
  • Tub Filling: The reservoir is filled first, with temperature adjustment via the mixing valve and monitoring on the fill temperature dial. The tub is then filled from the reservoir, with the water temperature checked again before the individual enters.
  • Bathing Cycle: The BathAire system can be activated for a warm environment and therapeutic air agitation. Shampoo and body wash can be dispensed directly into the hand or bath water.
  • Drying: The BathAire system can be kept on during drying to assist in warming the environment inside the tub.
  • Cleaning and Disinfection: After each bath, the tub and chair are rinsed, disinfected using the disinfectant wand, scrubbed with a provided brush, and then rinsed again. A contact time of 10 minutes is recommended for MasterCare Disinfectant/cleaner.
  • Storage: When not in use, storage areas should be locked, and the reservoir/tub fill lever should be in the open position.

Maintenance Features:

  • Battery Monitoring: The electronic scale provides a battery life indicator, prompting maintenance when the reading falls below 5.2.
  • Disinfectant/Shampoo Replacement: The system allows for easy replacement of one-liter jugs of MasterCare's disinfectant/cleaner and shampoo/body wash, with priming instructions provided.
  • Purge Cycle: The BathAire system's automatic purge cycle helps to dry the aerators, preventing moisture buildup.
  • Troubleshooting: The manual provides warnings and cautions for various operational aspects, including temperature control, transfer safety, and proper use of dispensing systems, to prevent damage and ensure safety. It also advises reporting maintenance problems before using the tub or transfer system.
  • Training Checklist: A training checklist is provided to ensure operators are familiar with the operation and safety instructions.