MAINTENANCE AND TROUBLESHOOTING
- Ⅳ -
§4.2.4 Operation of the TIG Lift welding method:
1. Selection of the welding method:
1) In the main interface, press the MENU key to enter the function selection interface;
2) In the function selection interface, rotate L Knob to select the TIG Lift welding method and
press it for confirmation. Refer to Fig. 1;
2. Selection and setting of welding parameters:
1) In the main interface, press the MENU key to enter the welding parameter setting interface;
2) In the welding parameter setting interface, rotate L Knob to select the parameter as
required and rotate R Knob to set a value for the parameter, afterwards, press L Knob or R
Knob for confirmation as shown below:
Welding parameters
available by rotating
L Knob
Welding
parameters
available by
rotating R Knob
Two/four Stroke
2T/4T
Pre-flow
0-2 S
Down Slope
0-10 S
Post Flow
0-10 S
3. Setting of welding current:
1) Press the ENTER key to enter the welding
interface as shown below:
2) In the welding interface, rotate L Knob to set
the welding current (10 - 200 A), and then press
it for confirmation.