6.4 When the generator is used to supply
power to two or more devices mentioned
above, connect or turn on the devices
one after another. First switch on high-
performance devices with high current
consumption or high starting current, and
then the devices at lower performance. (B14)
6.5 Connect as follows
All cable connections of the generator to the
domestic mains supply shall only be done by
qualied electricians. Improper connections
will damage the generator, or even cause a
re hazard.
6.6 Please carefully read these instructions,
before the generator supplies power
6.6.1 Start generator. (B12)
6.6.2 Connect electrical consumer loads
(B13,B14)
6.6.3 Turn on AC contact breaker (B15)
7. STOPPING THE ENGINE
7.1 Turn o AC protective switch. (B16)
7.2 Set the switch to OFF. (B17)
7.3 Turn the fuel cock to OFF. (B18)
NOTE: Set the switch to OFF to stop the
generator in case of emergency.
WARNING:
8. MAINTENANCE
The following table describes the maintenance intervals required and the type of
maintenance to be executed.
INTERVALLES
OBJET
or after 20 hours
for initial
operation
or every three
months
or every six
months
or every year
Check engine oil
check
Change engine oil
change
change
check
clean
Oilpan cup
clean
clean
clean
Filter of oilpan cup
Ignition plug
Tappet clearance
Check and
readjust
Clean piston housing
clean
Clean fuel tanke
Replace every three years