SERVICE AND SPECIAL FUNCTIONS
Table of Contents
Touch / TouchXL Console
41
Troubleshooting Guide
Treadmill Incline Calibration
After the following parts are replaced, the upper and lower limits of the treadmill incline motor must be
calibrated.
Upper Control Board
Motor Control Board*
Incline Motor*
*Refer to the appropriate Frame Troubleshooting for further information on replacement.
To automatically calibrate the treadmill incline motor:
1. Access the Product Dashboard by touching and holding on the Matrix logo, top center of display.
2. Press the “Machine Settings” button.
3. Type “3 0 0 1 enter” on the keypad that appears to access Machine Settings menu.
4. Touch on the “Calibrate” tab.
5. Touch on the “Calibrate” button to begin auto-calibration.
The treadmill will incline to its maximum, followed by decline to minimum. If calibration values are
appropriate, the console will display ‘Auto Calibration PASS’ and return to 0 incline.
The ADC values for incline top and incline bottom are also viewable; expected ranges are not currently
available.
Treadmill Overcurrent (OC) Protection & Treadmill TreadSense
See Treadmill Service Manual for more information on these settings. They should not be changed
without special instruction.
Ascent Trainer Incline Calibration
After the following parts are replaced, the upper and lower limits of the Ascent Trainer incline motor
must be calibrated.
Upper Control Board
Motor Control Board*
Incline Motor*
*Refer to the appropriate Frame Troubleshooting for further information on replacement.
To automatically calibrate the Ascent Trainer incline motor:
1. Access the Product Dashboard by touching and holding on the Matrix logo, top center of display.
2. Press the “Machine Settings” button.
3. Type “3 0 0 1 enter” on the keypad that appears to access Machine Settings menu.
4. Touch on the “Calibrate” tab.
5. Touch on the “Calibrate” button to begin auto-calibration.
The Ascent Trainer will move through its full incline range. If calibration values are appropriate, the
console will display ‘Calibration PASS’ and return to 0 incline.