Operation test
8
INSTALLATION
Before test operation, wiring safety inspection must be carried out carefully again.
1. Emergency switch operation: Every press of emergency switch, the 
air conditioner runs as  in the following order: 
Cool 
only  type: 
Cool   
Shut off 
Heat pump type: Cool   
Heat
Shut off 
2. Remote controller operation: If the indoor unit sounds like Di, Di when pressing I/O button,
     that indicates the air conditioner is under the operation of remote  controller. After that, press
     every button to test their functions.  
3.  operation: Open the front grille and press the check button. Switch on the powerCheck switch
    source and then the operation test is activated.  If the indicator  lamps light up at first and then
    go out in succession or the LED window of the indoor unit illuminates at first and then goes out, 
    the system  is under normal operation. If one of  the indicator lamps is flashing at all times, or 
   failure codes are displayed on the LED window of the indoor unit, the system has something 
   wrong and please check malfunction immediately.      
Check valve
Capillary tube
Capillary tube
Liquid side
2-way valve
Gas side
3-way valve
Accumulator
Compressor
4-way valve
Cross fan
Heat
exchanger
(Condenser)
Propeller fan
Heat
exchanger
(Evaporator)
 INDOOR UNIT   OUTDOOR UNIT 
Cooling
Heating
Gas leak check point
 BLOCK DIAGRAM
Refrigerant Cycle Block Diagram
11