FAULT DIAGNOSIS BY SYMPTOM
 
No cooling 
effect at all
Fan motor 
error
Fan motor or its capacitor faults.
Loose connection or badly contact.
compressor 
does not operate
Control circuit error. 
 Voltage may appear a little lower or higher.
 Loose or wrong connection.
 Compressor faults or jumps for overloading. 
Control circuit error. 
Leakage of 
refrigerant
 Recharge the refrigerant at leaking place.
Block of  the cooling 
system 
Poor cooling 
 efficiency
Insufficient 
refrigerant
  Some cracks, welding failure in the system.
Air filter is 
blocked
 No periodical cleaning.
Accumulated lampblack, dust or 
Accumulated lampblack, dust or contaminated 
ambient environment. 
Too high ambient 
temperature
The outdoor unit gets exposed to the sun for too 
long period.   
Air conditioning burden 
is not adequate for the
room
The capillary, pipeline are blocked or the valve 
is not open or the connecting tube is folded flat.   
The doors and windows are not closed well; 
too weak of input cooling power or too many
heat resources in the room. 
 Some leakage in the valve.
No cooling
The four-way 
valve error
Blockage in 
the system
 The valve is not completely open; the capillary or 
 Pipeline is half blocked.  
 Connecting  tube is folded flat.
 The distributing air of the four-way valve may have mixed 
together; the valve core or solenoid valve faults.  
Low airflow volume 
 Low fan motor frequency or capacitor is not 
functional. 
 Low fan speed or the fan motor faults.
 Extra fluorin is added during mounting.
 Mounting location is not suitable, such as near the wall. 
Air outlet is blocked or accumulated lampblack 
or dust is attached to the vane.
Poor efficiency of
heat dissipating on
the outdoor unit 
 Not for residential use.