EasyManua.ls Logo

MAXPhotonics MFSC 1500W CW Fiber Laser Series - 8-Error Listing

Default Icon
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6
37
8-Error Listing
The fault alarm points set by the laser include:
SN. Message Description Trouble shooting
1
Front lamp
warning
Laser internal
light path testing
fault
Operation leads to low output power
of laser such as low modulation
frequency, low peak power, low
cutting power
2
Pump overheat
warning
Overheat fault of
laser
For the internal overheat fault of
the laser, please check whether
the pre-set temperature of
water-cooling machine meets
the requirements; if this cause
is excluded, please contact
Maxphotonics.
3
Water cooling
plate overheat
warning
Overheat fault
of water cooling
plate
For overheat fault of water cooling
plate, please check whether the
pre-set temperature of water-
cooling machine meets the
requirements
4
Emergency stop
alarm
The emergency
stop switch is
pressed
Release the emergency stop switch,
the laser will work again after being
restarted; if this fault still exists,
please contact Maxphotonics.
5 Water flow error
Pipeline fault of
chiller or laser
Please check whether the water
pressure is normal,the water
pipeline is clear and replace the bad
water switch if need.
6
Overcurrent
warning
Overcurrent fault
of laser
If ''0-10V'' DA value exceeds
the pre-set value, the internal
overcurrent fault will occur; if the
fault is not caused by this reason,
please contact Maxphotonics.