Chapter 6
33
Cleaning protective lens with swabs
IMPORTANT:
◎ Do not reuse a lint-free optical wipe or swab.
◎ 2)Do not touch the protective lens of the fiber connector.
◎ Do not blow directly, or else new dirty will be brought.
Do not touch the tip of the cleaning swab with your fingers and use
each swab only once.
Cleaning is necessary before place the protective cover and sleeve.
Never blow air directly at the surface, because you could imbed
contaminants into the surface. Always blow across the surface!
If the fiber connector could not be installed in optical system
immediately, please cover it with the protective cap cleaned with
compressed air.