Chapter 6
34
5-Start Step
WARNING:
◎ Make sure that all the electrical connections (including cooling water
connections) are connected prior to use. All the connectors must be held
steady with screws if possible.
◎ NEVER look directly into the output fiber and make sure that you wear
the laser safety eyewear while operating the product.
◎ Make sure all power is removed from the laser when wiring.
Starting procedures are as follows:
(1)Start the water-cooling machine;
(2)Remove the end cap of the collimator;
(3)Make sure that the end surface of the collimator is clean and not
covered with impurities;
(4)Make sure that the emergency stop switch is turned on;
(5)Open the power supply of the laser;
(6)Place the key switch of the front panel on position "ON".
(7)Press the START button on the front panel. (For external control
method)
6- Mode Description
The working modes of the laser are as follows:
(1)Internal control: Control the output of the laser via control software.
This mode is used for checking whether the laser is normal or not, and
testing the laser power.
(2)External Control: Control the output of the laser via external control
line (EE, modulation, 0-10V analog voltage and START button). This
mode is used for cutting and welding.