Chapter 6
34
5-Start Step
WARNING:
Make sure that all the electrical connections (including cooling water
connections) are connected prior to use. All the connectors must be held
steady with screws if possible.
NEVER look directly into the output fiber and make sure that you wear
the laser safety eyewear while operating the product.
◎ Make sure all power is removed from the laser when wiring.
Starting procedures are as follows:
(1)Start the water-cooling machine;
(2)Remove the end cap of the collimator;
(3)Make sure that the end surface of the collimator is clean and not
covered with impurities;
(4)Make sure that the emergency stop switch is turned on;
(5)Open the power supply of the laser;
(6)Place the key switch of the front panel on position "ON".
(7)Press the START button on the front panel. (For external control
method)
6- Mode Description
The working modes of the laser are as follows:
(1)Internal control: Control the output of the laser via control software.
This mode is used for checking whether the laser is normal or not, and
testing the laser power.
(2)External Control: Control the output of the laser via external control
line (EE, modulation, 0-10V analog voltage and START button). This
mode is used for cutting and welding.