EasyManua.ls Logo

MaxPower CT80 - Troubleshooting; Control Panel Power Issues; Motor Not Running Diagnosis; Thruster Performance Issues

Default Icon
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual CT60 & CT80 April 2008
www.max-power.com 15
23. TROUBLESHOOTING GUIDE
Before contacting your nearest Max Power distributor, please check the below
troubleshooting guide.
Problem Check
The control panel does not light
up
• Check the 6 wire connector behind the joystick
• Check the thruster's electronic control box 6 wire
connector
• Check the circuit breaker / switch in the boat's
main DC distribution panel
• Check the control box's power fuse (8 A)
The relay is clicking but the motor
is not running
• Check the motor's power fuse
• Check the main battery isolator
• Check the internal relay contacts
• Check battery conditions and connections
The motor is running but the
thruster is not working
• Check the propellers are fitted
• Check the motor / drive leg assembly
• Check that the tunnel is not obstructed or the
propellors blocked
The thruster lacks power
• Check the propellers are fitted
• Check the size of the batteries
• Check the batteries are sufficiently charged
• Check the connections are tightened correctly
• Check the power cables sections
(See p. 6 : Recommended cable sections)
24. WORLDWIDE DISTRIBUTION NETWORK
To locate the nearest Max Power distributor, please consult the section
"Worldwide Distribution" on our website: www.max-power.com

Related product manuals