16
60A
70A (only for 5KW model)
80A (only for 5KW model)
14
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected, battery
charge voltage and low DC cut-off
voltage can be set up in program 17,
18 and 19.
Pylontech battery
If selected, programs of 11, 17, 18
and 19 will be automatically set up.
No need for further setting.
WECO battery
If selected, programs of 11,17 , 18,
19 and 20 will be auto-configured per
battery supplier recommended. No
need for further adjustment.
Programs of 20 and 21 parameters
refer to SOC of battery.
Soltaro battery
If selected, programs of 11, 17, 18
and 19 will be automatically set up.
No need for further setting.
17
Bulk charging voltage
(C.V voltage)
Default setting: 56.4V
If self-defined is selected in program 14, this program can be
set up. Setting range is from 48.0V to 64.0V. Increment of
each click is 0.1V.
18
Floating charging voltage
Default setting: 54.0V
If self-defined is selected in program 14, this program can be
set up. Setting range is from 48.0V to 60.0V. Increment of
each click is 0.1V.
19
Low DC cut off battery voltage
setting
Default setting: 40.8V