SOLID-STATE THERMOSTAT DESCRIPTIONS
1. FRONT PANEL COMMANDS
1.1 KEY FUNCTION
To display target set point; in programming mode it selects a parameter or
conrms an operation.
To start a manual defrost
To see the last temperature alarm; in programming mode it browses the
parameter codes or increases the display value
To see the last temperature alarm; in programming mode it browses the
parameter codes or decreases the display value
KEY COMBINATION
To lock & unlock the keyboard
To enter programming mode
To return to the room temperature display
LED MODE FUNCTION
ON Compressor Enabled.
Flashing
Programming Phase.
Anti-short cycle delay enabled.
ON Defrost Enabled.
Flashing
Programming Phase.
Drip time in progress.
ON Fans Enabled.
Flashing Fans delay after defrost in progress.
ON A temperature alarm happens.
1.2 LEDS