Proble
m
kinds
Check
part or
point
Possible Cause
Probable Correction
The
machin
e don't
operate
Plug
The icemaker is
unplugged.
Plug the icemaker in.
Socket
Socket is damaged
Check and replace
Power
switch
The icemaker power
switch turns to OFF.
Turn the icemaker power switch
to ICE.
Fuse
The fuse is blown.
Replace fuse.
Wiring
connection
Some wiring connection
is incorrect or loosed
Check and re-connect
Voltage
The voltage of the power
supply is low.
Add manostat.
Ice full
probe
The ice full probe is out
of function.
Replace a new one.
Ice full
probe
The ice full probe is
covered by something
Clear the probe and make the
ice-full probe is free.
wiring
Some wiring is damaged
Replace a new one
Electric
component
Some electric component
fail
Find the controller, press the
mode button to change the mode.
It is helpful to judge which part is
out of function
Controller
The controller fail
Replace a new one
Water
System
Water
supply tap
The water supply tap is
turn off.
Turn on the water supply tap.
Water
supply
pipe
The water supply pipe
is not proper connected or
maybe kinked
Reconnect the water supply pipe.
Water line
Some water line leaks.
Plug into again.
The water line blocks
Clean it, see user and care
manual "ice making system
cleaning"
Water supply pressure is
lower.
Adjust the water supply pressure
within the range of stated range.
Water inlet
Water inlet blocks
Check and clear it
Water
pump
Water pump damages
Replace water pump.
The room temperature is
out the stated range, the
water pump stop
automatically.
Make the temperature returns
within the stated range.
The lines of the water
pump loose.
Plug into again
The housing of water
pump leaks.
Replace water pump.