inlet tube of pump.
Loosen the screws, replace a new one.
Reverse the above step to reassemble.
Replace the cooling system components
Replace the condensing components, See Figure “cooling system”
1.Replace the compressor and the compressor kit (includes relay, thermal protect).
If only need replace the compressor kit, remove the rear, locate the compressor, take the clip,
open the cover, replace the wrong,
Reverse the above step to reassemble.
If need replace the compressor, remove the rear cover, and cabinet, locate the compressor.
Unplug the lines and taken out the earth line, add low side access valve, open the
Process/Suction, evacuate refrigerant, take out the compressor, replace a new one, joint together,
then recover refrigerant, weigh in the nameplate charge.
Reverse the above step to reassemble.
2. Replace the fan motor and fan blade.
Remove the front panel, rear and cabinet.
locate the fan motor, unplug the lines connecting with the fan motor, loosen the screws of
holding fan motor bracket.
Replace a new one, If only need replace the fan blade, loosen the screws holding the fan blade,
taken out the damaged, replace a new one.
Reverse the above step to reassemble.
3. Replace the hot gas valve, drier and evaporator.
Remove the rear cover.
Locate the drier and hot gas valve, add low side access valve, recover refrigerant, replace the
drier and hot gas valve, evacuate and weigh in the nameplate charge.
Reverse the above step to reassemble.
If need replace the evaporator.
Remove the rear, locate the evaporator, add low side access valve, open the process/suction ,
weld open the two welds, replace a new one. Recover refrigerant, evacuate and weigh in the
nameplate charge.
Reverse the above step to reassemble.