Electrical
requirements
Electrical Shock Hazard
Ilectrical ground is required on
his appliance.
10 Not ground to a gas pipe.
10 Not change the power supply
:ord plug. If it does not fit the
>utlet, have a proper outlet
nstalled by a qualified
alectrician.
>o Not have a fuse in the neutral
>r grounding circuit. A fuse in the
neutral or grounding circuit could
!esult in electrical shock.
)o Not use an extension cord
with this appliance.
Check with a qualified
electrician if you are in doubt as
o whether the appliance is
lroperly grounded.
3rounding wire must be
:onnected to grounding screw
ocated in lower right comer of
lir conditioner when air
:onditioner is in cabinet.
:ailure to follow these instructions
:ould result in death or serious
njury.
If codes permit and a separate
grounding wire is used, it is
recommended that a qualified
electrician determine that the
grounding path is adequate.
Check wiring requirements. A
three-wire, single-phase, &Hz,
AC-only electrical supply is
required on a separate circuit. A
15-amp time-delay fuse or circuit
breaker is required. Copper wire
(#14 gauge) is required. The
model/serial rating label is located
behind the front panel above the
coil area.
model/krial rating label
Specific electrical requirements
are listed in the chat-t. Follow the
requirements for the rating listed
on the model/serial rating label.
Wiring
requirements
Plug Type A
power
supply cord
I 15-volt -
lOX5v min.,
126.5~ max.
7.5amp
vating or less -
3 double
3utlet is
clcceptable.
7.6 through
I 2-amp ratings -
Jse only a single
Met and a
,eparate circuit.
Plug Type B
l/A”
grouktlng prong
230/208-volt
197.6~ min.,
253~ max.
12-amp rating or
less - use a single
outlet and a
separate circuit.
Re2emdmended grounding
For your personal safety, this
appliance must be grounded.
This appliance is equipped with
a power supply cord having a
3-prong grounding plug. To
minimize possible shock hazard,
the cord must be plugged into a
mating, 3-prong grounding-type
wall receptacle, grounded in
accordance with the National
Electrical Code, ANSVNFPA 70 -
latest edition, (* see Page 2), and
all local codes and ordinances. If
a mating wall receptacle is not
available, it is the personal
responsibility and obligation of the
customer to have a properly
grounded, 3-prong wall
receptacle installed by a
qualified electrician.
Now start...
With air conditioner in room
where it will be installed.
1
Push down on front panel
n
and pull panel towards
you to remove from cabinet.
Injury Hazard
Maintain a firm hold on the air
conditioner to prevent it from
falling out of the opening during
installation.
Failure to follow this instruction
could result in serious injury.
Page 3