- 5 -
HYDRAULIC SYSTEM
1. Remove the RED Plug in the pump assembly and replace with the
supplied BLACK plug. This is the reservoir venting system
and damage or inoperability may result if not changed out.
2. Attach the hydraulic hose to the pump. Be sure to use a
quality thread sealer on both connections
3. Attach an air line fitting for your shop air to other end of the
pump.
4. Push the pump foot pedal to the release position (TOE END) to
relieve all internal pressure.
5. Push the MALE hose end, from the pump, into the FEMALE
Cylinder fitting.
6. Thread the retainer collar hand tight. NOTE: This procedure will insure that the male & female fittings
positively seat against each other, eliminating any possibility of air locking. CAUTION Failing to follow
this procedure may cause the cylinder to not retract and / or leak.
BLEED THE CYLINDER
7. Connect a compressed air supply (90PSI) to the pump.
8. Elevate the pump and hose above the cylinder.
9. Push the hydraulic pump pedal HEEL END to actuate the
cylinder. Run the cylinder out about half way. Release the pump
by pressing on the TOE END of the pedal. Repeat this process
three or four times or until the ram cylinder movement is smooth.
be changed to
BLACK Plug
Hydraulic Hose
Connector
Retract
Pump
Release Pressure