PROPER STORAGE
Preparing your Portable Power Steam Cleaner for storage is quick and simple. When you have n-
ished your steaming tasks, follow the steps listed below.
1. Set Lighted On/Off Switch to “O” (off) position and unplug power cord from electrical outlet.
2. Allow unit to cool (30 minutes for complete cooling).
3. Press and hold Steam Trigger to release all remaining steam pressure.
4. Remove all accessories from unit.
5. Unscrew and remove Reservoir Cap. Drain any remaining water from Reservoir into a sink or tub –
this will help to minimize mineral build-up and prevent over-lling during your next use.
Loosely replace Reservoir cap.
NOTE: Do not overtighten Reservoir Cap when storing, as this may make it difcult to remove
during next use.
6. Store accessories safely away - smaller accessories can be conveniently stored in the storage
compartment located on the Cord Wrap.
7. Loosely wrap power cord around Cord Wrap and store Portable Power Steam Cleaner in a cool,
dry location.
CARE & MAINTENANCE
A common maintenance need for steam appliances is the removal of build-up caused by high
mineral content in many municipal water supplies. This mineral build-up may limit the
effectiveness and reduce the life of your Portable Power Steam Cleaner.
The best way to minimize mineral build-up is to use distilled or de-mineralized water when
using your Portable Power Steam Cleaner. If you are unable to use distilled water, it is recommended
that the following procedure be followed monthly to help remove any mineral build-up:
To remove mineral build-up:
1. Set Lighted On/Off Switch to “O” (off) position and unplug power cord from electrical outlet.
2. Allow unit to cool (30 minutes for complete cooling).
3. Press and hold Steam Trigger to release all remaining steam pressure.
4. Remove all accessories from unit.
5. Unscrew and remove Reservoir Cap, and drain any remaining water from Reservoir into a sink or
tub.
6. Fill Measuring Cup with 16 oz (474 ml) distilled vinegar. Carefully pour vinegar into Reservoir.
7. Slowly shake or move unit around to agitate vinegar.
8. Allow to stand for at least 40 minutes, or more if possible.
9. Drain vinegar from Reservoir.
10. Rinse Reservoir with fresh water, drain and repeat until vinegar odor dissipates.
11. Loosely replace Reservoir Cap and continue with normal storage procedure, as outlined in
Proper Storage section above.