EasyManua.ls Logo

mcmurdo E3 - EPIRB De-activation and Refitting; De-activation Procedure; Re-fitting into Wall Bracket

mcmurdo E3
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
1
2
Slide cover to right
Press READY button
READY
HOLD TO
TEST
1
Insert
antenna
2
3
Push
backwards
Push firmly
into cup
Push down
until clip locks
4
4.6 De-activation
If the E3 was activated by mistake or if the emergency ends then the E3 can be
reset back to its “ready” state as follows…
Remove EPIRB from any water
and dry its sea switch contacts.
Wait 8 seconds for sea switch to turn off.
If EPIRB is still flashing then it must have
been turned on manually…
Slide the switch cover fully to the right.
Press and release READY button.
If EPIRB is still flashing then it has a fault.
Refer to section 5 on “False alarms”.
4.7 Battery condition
If your E3 has been activated for a cumulative period in excess of 2 hours then its
battery will need replacing. This is necessary to ensure that the next time it gets
used it will operate for the full 48 hours required by government regulations. See
section 9.3 for battery replacement instructions.
4.8 Re-fitting E3 into wall bracket
The E3 is now in its “ready” state, but its sea switch is still armed and will activate if
it gets wet. To fully de-activate the E3 it must be returned to its mounting bracket,
where a magnet hidden in the bracket will make the E3 safe. Follow the appropriate
instructions below…