Installation, Operation and Maintenance Manual
IOMM ACZ1
Group:
Chiller
Part Number
: 330262002
Effective:
December 2001
Supersedes:
New
Air-Cooled Scroll Condensing Units
ACZ 010A – ACZ 039A
10 to 43 Tons, 35 to 150 kW
R-22, 60 Hertz

Questions and Answers:

McQuay ACZ 016A Specifications

General IconGeneral
BrandMcQuay
ModelACZ 016A
CategoryHeat Pump
LanguageEnglish

Summary

Introduction

Inspection Procedures

Guidelines for checking units upon arrival for damage and correctness.

Installation Guidelines

Instructions for qualified personnel on unit installation.

Handling Precautions

Advice on safely moving and lifting the unit.

Location and Placement

Service Access Requirements

Ensuring accessibility to unit components for service.

Clearances and Airflow

Condenser Airflow Management

Importance of maintaining unobstructed airflow for efficiency.

Refrigerant Piping Best Practices

Piping Introduction and Concerns

Importance of proper piping for system reliability and performance.

Suction Line Design Guidelines

Recommendations for sizing and routing suction lines.

Refrigerant Piping Design

Suction Line Sizing Calculation

Steps to determine appropriate suction line sizes.

Liquid Line Design

Liquid Line Sizing Criteria

Factors influencing liquid line sizing and selection.

Unit Start-up and Shutdown Procedures

Pre Start-up Checklist

Essential checks before initial unit operation.

Unit Start-up Sequence

Step-by-step instructions for starting the unit.

Electrical Data and Wiring

Field Wiring Requirements

General rules for field wiring connections.

Electrical Wiring Diagram

Typical Field Wiring Diagram

Schematic illustrating electrical connections.

MicroTech II Controller Features

Compressor Staging and Protection

How compressors are staged and protected.

MicroTech II Controller Setpoints & Alarms

Detailed Setpoint Table

Comprehensive list of configurable setpoints.

Equipment Protection Alarms

Alarms that trigger rapid compressor shutdown.

MicroTech II Controller Alarms

Shutdown and Limit Alarms

Conditions causing unit shutdown or limiting operation.

MicroTech II Controller Menu Operations

Process for Changing Setpoints

Step-by-step guide to modifying setpoint values.

MicroTech II Controller Setpoint Adjustment

Example of Setpoint Change

A practical example of changing a unit setpoint.

MicroTech II Screen Definitions - Alarm

Active Alarms Display

Information on current unit alarms.

MicroTech II Screen Definitions - Set

Setpoint Adjustment Procedures

General steps for modifying setpoints.

MicroTech II Limit Alarms Configuration

Low Evaporator Pressure Limits

Setting thresholds for low evaporator pressure alarms.

Evaporator Freeze and Flow Proof Alarms

Configuring freeze protection and flow interlocks.

High Condenser Pressure Limits

Setting thresholds for high condenser pressure alarms.

Service and Maintenance

Thermostatic Expansion Valve

Role in maintaining superheat for compressor life.

Troubleshooting Common Issues

Compressor Operation Problems

Diagnosing and resolving issues like not running or noise.

Pressure Related Issues

Troubleshooting high/low discharge and suction pressures.

Unit Loading Problems

Addressing issues with unit loading or unloading intervals.

Compressor Oil Loss

Diagnosing and fixing compressor oil loss.

Electrical Fault Diagnosis

Troubleshooting motor overloads, blown fuses, and thermal switches.