62
M5MSY-2010 Electrical Data
Electrical Data - Heat pump
Outdoor
MODEL OUTDOOR UNIT M5MSY20BR M5MSY25BR M5MSY30BR
OUTDOOR MOTOR
INSULATION GRADE CLASS E
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
RATED INPUT POWER W 72 68.3 68.3
RATED RUNNING CURRENT A 0.93 0.79 0.79
MOTOR OUTPUT W 61 61 61
COMPRESSOR
INSULATION GRADE CLASS E
POWER SOURCE V/Ph/Hz Inverter
CAPACITOR mF ---
RATED INPUT POWER
(COOLING)
W 1183 1420 1420
RATED INPUT POWER
(HEATING)
W 1264 1491 1491
RATED RUNNING CURRENT
(COOLING)
A 4.69 6.7 6.7
RATED RUNNING CURRENT
(HEATING)
A 4.09 5.58 5.58
LOCKED ROTOR AMP. A 30 30 30
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.