EasyManuals Logo
Home>McQuay>Air Conditioner>MDS030A

McQuay MDS030A User Manual

McQuay MDS030A
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
page 20
Model: MDS040A
Model: MDS040AR
C
1-
3
F
a
n
1
KM
PWMV
F
U
O
F
F
O
F
F
PWMV
KM
F
U
22
0
V~
/50
H
z
N
L
5
N
11
12
F
a
n
2
O
F
F
HP
LP
3
1
3
14
J
P
1
J
P
2
O
F
F
r
ed
r
ed
2
7
8
1
0
Com
p
resso
r
PT
C
N
red
b
l
ue
whit
e
O
F
F
ON
J
2.
6
b
l
ue
M
~
M
~
C2
C3
L
P
HP
Connectin
g
indoor units communication
DLT
O
D TEMP.
I
nL
e
t
TRAN
-
L
4WV
PWMV
F
IXED
CO
MP
D
I
G
CO
MP
HI
-
FAN
MID
-
FAN
LO
W-FAN
C
-BTM
RTN
Tr
a
n
s
f
o
rm
er
Mi
d
L
e
t
y
ellow
b
rown
o
ran
g
e
b
l
ue
RY2
RY1
R
Y
3
RY
5
RY4
RY
6
RY7
J1
J2
J
P
1
J
P
2
R
CM
S
C
KM
2T1
4T2
6
T
3
5
L
3
1L1
3
L
2
PT
C
C1
J
1.
1
J
1.
7
LIVE
NE
U
TRA
L
NE
U
TRA
L
O
V-
CO
MP
3
O
V-
CO
MP
2
O
V-
CO
MP
1
LP
HP
Air dischar
g
e temperature sensor of the di
g
ital compressor (TH1
)
Coil middle tem
p
erature sensor
(
TH5
)
Return air tem
p
erature sensor
(
TH3
)
Ambient tem
p
erature sensor
(
TH2
)
AI-I
N
A
G
N
D
B
McQua
y
N
o
t
es:
2:
1:
Factory wirin
g
Field wirin
g
3:
4:
If the unit is connected at the end of the bus
,
JP1 and
J
P2 are
O
N
.
S
y
mbo
l
S
y
mbo
l
Descri
p
tio
n
Com
p
ressor start-u
p
unit
C
ontacto
r
Ca
p
acito
r
Hi
g
h pressure switc
h
Descri
p
tio
n
F
use
S
olenoid valv
e
Low
p
ressure switc
h
Descri
p
tion of com
p
onents and
p
arts:
Jumper settin
g
s
:
DIP switch J2 settin
g:
y
ellow
b
r
o
wn
o
ran
g
e
b
l
ue
Descri
p
tion of com
p
onents and
p
arts:
C
1-
3
F
a
n
1
KM
S
y
mbo
l
S
y
mbo
l
4WV
EXV
PWMV
F
U
Jumper settin
g
s
:
O
F
F
KM
F
U
22
0
V~
/50
H
z
N
L
N
11
12
EXV
F
a
n
2
O
F
F
O
F
F
O
F
F
HP
LP
3
1
3
14
J
P
1
J
P
2
O
F
F
r
ed
r
ed
2
7
8
1
0
Com
p
resso
r
PT
C
N
r
ed
b
l
ue
whit
e
O
F
F
O
F
F
J
2.
6
DIP switch J2 settin
g:
M
~
M
~
C2
LP
HP
Connectin
g
indoor units communicatio
n
DLT
C
N
1
O
D TEMP.
I
nL
e
t
4WV
PWMV
F
IXED
CO
MP
D
I
G
CO
MP
HI
-
FAN
MID
-
FAN
LO
W-FAN
C
-BTM
RTN
Tr
a
n
s
f
o
rm
er
b
rown
o
ran
g
e
y
ellow
b
l
ue
O
utLet
M
i
d
L
e
t
y
ellow
b
rown
o
ran
g
e
b
l
ue
RY2
RY1
RY
3
RY
5
RY4
RY
6
RY7
J1
J2
JP1
JP2
R
CM
S
C
KM
2T1
4T2
22
3
L
2
21
PT
C
C1
J
1.
7
N
o
t
es:
2:
1:
Factory wirin
g
Field wirin
g
3:
4:
and
J
P2 are
ON
.
R
C
LIVE
NE
U
TRA
L
NE
U
TRA
L
O
V-
CO
MP
3
O
V-
CO
MP
2
O
V-
CO
MP
1
LP
HP
AI
-
IN
A
G
N
D
B
McQua
y
Coil outlet tem
p
erature sensor
(
TH6
)
Coil middle tem
p
erature sensor
(
TH5
)
Coil inlet tem
p
erature sensor
(
TH4
)
Return air tem
p
erature sensor
(
TH3
)
Ambient tem
p
erature sensor
(
TH2
)
Air dischar
g
e temperature sensor of the di
g
ital compressor (TH1
)
Descri
p
tio
n
Com
p
ressor start-u
p
unit
Four-wa
y
valv
e
C
ontacto
r
Ca
p
acito
r
Hi
g
h pressure switc
h
Descri
p
tio
n
F
use
Electric ex
p
ansion valv
e
S
olenoid valv
e
Low
p
ressure switc
h
Sur
g
e suppresso
r
S
haf
t
h
ea
t
er

Other manuals for McQuay MDS030A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the McQuay MDS030A and is the answer not in the manual?

McQuay MDS030A Specifications

General IconGeneral
BrandMcQuay
ModelMDS030A
CategoryAir Conditioner
LanguageEnglish

Related product manuals