EasyManua.ls Logo

McQuay MDS030A - Page 26

McQuay MDS030A
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
page 25
Model: MDS150BR
KM2
O
L
2
T1
T2
O
L
1
KM1
1
8
R
380
V
/3
N~
/50
H
z
T
N
3
.
3A
14.
0
O
L
1
O
L
4
ON
S3
.
3
ON
S
2.
3
O
F
F
S3
.
2
ON
S3
.
4
L1
T2
KM
5
O
L
5
1
9
21
2
3
O
L
4
KM4
2
6
2
5
24
J
1
8
HP
O
L
4
1
5
J1
O
L
5
L
HP
3
PMW
KM
5
S
V1
1
10
11
PMW
S
V2
4
2
FANH
FANL
4WV
L
O
W-
I
FIX2-
OL
O
L
3
O
L
1
14
13
DI
G
-
OL
V2-
TR
TH
3
HI
-
1
TH12
TH11
F
U
71
T
EXV1
EXV4
L
O
W-
U
HI-
U
KM
5
KM4
TH
5
TH7
FIX2
FIX1
5
17
T1
T2
KM
3
O
L
2
12
8
O
L
3
14.
0
30
31
32
33
LPT
1
3
2
M
~
M
~
S2
S1
S3
MD
S
-
M
Bp
c
Ap
c
Ain
Bin
y
ellow
red
b
l
ue
b
l
ac
k
b
rown
w
hit
e
y
ellow
red
b
l
ue
red
b
l
ue
y
ellow
red
red
b
l
ue
red
b
l
ac
k
w
hit
e
red
b
l
ac
k
w
hit
e
O
vercoolin
g
circuit outlet temperature sensorTH11
Connecting central control system
o
Connecting the indoor unit
r
h
ea
t
er
S
haft
h
ea
t
er
h
ea
t
er
Constant-s
p
eed
com
p
ressor
1
Fan motorDi
g
ital compresso
r
Constant-s
p
eed
com
p
ressor
2
S1.3~S1.8 set the number of indoor units. S2.1 sets the unit as a master/slave. For details of S2.4~S2.8
,
see the instructions
.
1:
3
:
2:
N
o
t
es:
Field wirin
g
Factory wirin
g
Fuse
Overload
p
rotectio
n
C
ontacto
r
KM
Low
p
ressure senso
r
Hi
g
h pressure switc
h
LPT
H
P
R
e
v
e
r
s
ion
Descri
p
tion of the com
p
onents and
p
arts
:
DB
3A
4W
V
Tr
a
n
s
form
er
Hi
g
h pressure senso
r
HP
T
Model: MDS150B
KM2
OL
2
T1
T2
T
3
OL
1
KM1
R
380
V
/3
N~
/50
H
z
T
N
3
.
3A
O
L
5
14.
0
O
L
1
O
L
4
ON
S
2.
3
1.
8A
ON
S3
.
4
TH4
L1
T2
T1
T
3
KM
5
O
L
5
21
2
3
O
L
4
KM4
2
6
24
J
1
8
HP
O
L
4
1
5
16
J1
O
L
5
L
HP
3
KM
3
PMW
KM1
KM4
KM
5
S
V1
1
10
11
PMW
S
V2
4
2
FANH
FANL
L
O
W-
I
FIX2-
OL
O
L
3
O
L
1
14
13
DI
G
-
OL
V1-
V2+
V2-
TR
V1+
TH
3
HI
-
1
TH
6
F
U
71
T
L
EXV4
EXV1
EXV4
TH2
KM
5
KM4
TH
5
TH7
FIX1
D
I
G
5
17
T1
T2
KM
3
T
3
O
L
2
12
KM2
8
O
L
3
14.
0
30
~
M
M
~
M
~
MD
S
-
P
M
~
MD
S
-
M
Bin
Bp
c
Ap
c
Ain
L
O
W-
U
HI-
U
LPT
1
2
3
red
b
l
ac
k
w
hit
e
red
b
l
ac
k
w
hit
e
b
l
ack
whit
e
A
ir dischar
g
e temperature sensor of the di
g
ital compressor TH1
Connecting central control system
n
Connecting the indoor unit
S1.3~S1.8 set the number of indoor units. S2.1 sets the unit as a master/slave. For details of S2.4~S2.8
,
see the instructions
.
1:
3:
2:
N
o
t
es:
Field wirin
g
Factory wirin
g
F
use
Overload
p
rotectio
n
C
ontacto
r
KM
Hi
g
h pressure switc
h
LPT
HP
OL
R
e
v
e
r
s
ion
Descri
p
tion of the com
p
onents and
p
arts
:
DB
3A
F
U
S
olenoid valv
e
Hi
g
h pressure senso
r
HPT
Tr
a
n
s
form
er
TR
y
ellow
red
b
l
ac
k
b
r
o
wn
w
hit
e
y
ellow
red
b
l
ue
red
b
l
ue
y
ellow
red
b
l
ue
y
ellow
red
b
l
ue
Constant-s
p
eed
com
p
ressor
1
Fan motorDigital compresso
r
Constant-s
p
eed
com
p
ressor
2

Other manuals for McQuay MDS030A

Related product manuals