5.2 Buttons
5.2.1 Silk Screen of Buttons
Fig. 5-3 Silk screen of buttons
5.2.2 Instruction to Function of Buttons
Tab l e 3 .2
No. Description Function of Button
1 Enter/cancel
(1) Function selection and canceling;
(2)
Press it for 5s to enquiry the outdoor ambient temperature.
2 Ÿ
6 ź
(1)
Running temperature setting of indoor unit, range
:16~30qC
(2) Timer setting, range:0.5-24hr
(3) Switchover between quiet/auto quiet
3 Fan Setting of high/middle/low/auto fan speed
4
Mode
Setting of cooling/heating/fan/dry mode of indoor unit
5 Function Switchover among these functions of air/sleep/turbo/save/e-heater/blow/quite
7
Timer Timer setting
8
On/off
Turn on/off indoor unit
4 Mode
and
2 Ÿ
Memory function
Press Mode and Ÿ
for 5s under off state of the unit to Enter/cancel key
memory function (If memory is set, indoor unit will resumer original
setting state after power failure and then power recovery. If not, indoor
unit is defaulted to be off after power recovery. Memory function is
set to be before outgoing.)
2 Ÿ
and
6 ź
Lock
Upon startup of the unit without malfunction or under off state of the unit,
press Ÿ ź key at the same time for 5s in to lock state. In this case, any other