MDS 05-2708A01, Rev. D MDS TransNET I&O Guide 23
The TransNET Configuration Software provides access to all of the radio’s
capabilities with the benefit of context-sensitive help. The program is shipped
as part of the TransNET support CD included with every order (CD P/N
03-2708A02)
6.2 User Commands
A series of tables begin on the next page that provide reference charts of
various user commands for the transceiver. See “Detailed Command Descrip-
tions” on Page 28 for more details.
Entering Commands
The proper procedure for entering commands is to type the command,
followed by an keystroke. For programming commands, the
command is followed by , the appropriate information or values, and
then .
Table 7. Network Configuration—Master Station
COMMAND DESCRIPTION
AT [ON, OFF]
Details Page 29
Enables Master station to emulate a modem
and respond to AT commands
BUFF [ON, OFF]
Details Page 30
ON = Seamless data
OFF = Fast byte throughput.
FEC [ON, OFF]
Details Page 33
Sets/disables FEC
(Forward Error Correction) setting.
HOPTIME [7, 28]
Details Page 34
Displays hop-time or sets it to 7 or 28 ms.
LPM [1, 0]
Details Page 36
Used at Master to set all associated stations
in an energy-conservation mode.
1 = Low-power mode enabled network-wide
0 = Disable low-power mode (Default)
REPEAT
Details Page 38
Sets/displays the xed downstream re-send
count.
RETRY [0–10]
Details Page 38
Sets/displays the maximum upstream re-send
count for ARQ (Automatic Repeat Request)
operation
SAF [ON, OFF]
Details, page 40
Enables/disables the store-and-forward func-
tion for the network controlled by this Master
unit.
SKIP [NONE, 1...8]
Details, page 41
Skip one or more frequency zones
ENTER