Page 29 XX69RT Series - Service & Parts Manual
November 2022Section 6 - Maintenance
7. Using a mild solvent, carefully wash the cap venting system. Dry using low pressure compressed
air. Repeat this procedure beginning with step 6.
8. Install the breather cap onto the hydraulic tank.
D-9 Test the Flashing Beacons
Flashing beacons are used to alert operators and ground personnel of machine proximity and motion.
The ashing beacons are located on both sides of the machine.
1. Turn the ground red Emergency Stop button clockwise to the on position. Pull out the platform
red Emergency Stop button to the on position.
2. Turn the key switch to ground controls and start the engine from ground controls.
Result: The beacons should ash.
3. Turn the key switch to platform controls and start the engine from platform controls.
Result: The beacons should ash.