Questions and Answers

  • T
    Tiffany PayneAug 8, 2025
    What to do if MEDIX Econoneb air compressor will not operate?
    • J
      Jeffrey CooperAug 8, 2025
      If your MEDIX Medical Equipment air compressor won't operate when switched on, there are several things you can check. First, ensure the mains lead is securely connected at both ends. If the unit has a 3-pin plug (UK), remove it and check the fuse (3.15AL 25mm long). Also, check the mains fuse in the control panel (T1AL 20mm long) and in the mains inlet socket after disconnecting the unit from the electricity supply. If none of these steps work, the machine may have an internal fault and should be returned to the point of purchase or an authorized person for examination.
  • V
    vickie70Aug 18, 2025
    Why does nebulizing take longer with MEDIX Medical Equipment?
    • D
      Dominique ColonAug 18, 2025
      If the time taken to nebulize significantly increases with your MEDIX Medical Equipment, check that the driveline tubing is not kinked or leaking, and replace it if necessary. If the problem persists, you should service the compressor.
  • L
    Latoya JamesAug 28, 2025
    How to fix MEDIX Medical Equipment nebulizer chamber when it bubbles?
    • N
      nathantuckerAug 29, 2025
      If your MEDIX Medical Equipment nebulizer chamber bubbles or produces little to no mist, first check the inlet filter and replace it if necessary. If the issue continues, wash the nebulizer chamber. If the problem still occurs after washing, replace the nebulizer chamber.

Summary

Product Identification

Symbols

Introduction

Starter Kits

Notes on Nebuliser Care

Operating Instructions

Filling the Nebuliser Chamber

Instructions for filling the nebuliser chamber with medication.

Administering the Medication

Steps for using the nebuliser with medication and patient position.

Cleaning

Changing the Attachments

Replace Filters for the Econoneb;Turboneb 2

Replace Fuse

Servicing

Safety Precautions

Troubleshooting

Technical Specifications

Particle Size Distribution

Storage

Guarantee

EMC (Electromagnetic Compatibility) Declaration

Disposal Instruction

Spares and Accessories

MEDIX Econoneb Specifications

General IconGeneral
Particle Size<5 μm
Particle Size (MMAD)≤5 μm
Noise Level≤55 dBA
Compressor TypePiston
TypeCompressor Nebulizer
Power Supply220-240V AC, 50/60 Hz