Megger"
OPTIONAL
ACCESSORIES
Protective
Cover
A
tough
cover
made
of
heavyweight, reinforced, vinyl-coated
nylon
is available for protecting the test
set
from oil,
dust
or
other
particulate matter during storage.
It conforms to
Mil-C-43006D
and
passes Mil-C-20696B test for
oil
and
hydrocarbon resistance.
It
will withstand continuous
exposure
to
temperatures ranging from -40
to
+ 180
0
F
(-40
to
+820
C),
and
the fire-retardant material is treated
with
fungal
and
ultraviolet ray inhibitors.
Input
Autotransformer
If
the
nominal input voltage for the test set is
not
available,
or
if
use
at
different locations requires the
use
of
a variety
of
input
voltages,
an
autotransformer may
be
used.
ORDERING
INFORMATION
Item
(Qty)
Cat.
No.
Model
DDA-3000 DDA-3000
Model
DDA-3001 DDA-3001
Model
DDA-3002 DDA-3002
Model
DDA-6000 DDA-6000
Model
DDA-6001 DDA-6001
Model
DDA-6002 DDA-6002
Included Accessories
Standard stab sets
CBS-1
and
CBS-2
Leads
Timer
leads, 12
ft
(3.7 m) [2] 2997
Input
leads,
15-ft
(4.5-m), 4/0 cable [2] 17163
Fuses
Fuse
500
V,
6 A [2]
9377
Fuse
250
V,
1.5 A [5]
950
Stab series
bar
[1]
5532
Instruction manual [1]
17176
Optional
Accessories
Input
autotransformer
AT-1,
AT-4
Leads included
with
input
autotransformer
Interconnect
leads,
10-ft
(3-m), 4/0 cable [2]
17164
Jumper
lead [1]
Protective cover
Model
CBS-3
stabs
UK
Archcliffe
Road,
Dover
CT17
9EN
England
T (0) 1
304
502101
F
(0)
1
304
207342
17527
PC-1
Contact Technical
Sales
UNITED
STATES
4271
Bronze
Way
Dallas,
TX
75237-1019
U5A
T 1
800
723
2861
T 1
214
333
3201
F 1
214
331
7399
DDA-3000
and
DDA-6000
Universal Circuit Breaker
Test
Sets
The multitapped autotransformer is
equipped
with a
power
on/off
switch, appropriate sockets, plugs, interconnect
and
tap selector
cables.
It
is
housed
in a rugged sheet-metal enclosure with casters
and
handles.
All
voltages are single-phase with a tolerance
of
±5%.
Input taps
of
240 volts
and
below
are
not
recommended
for obtaining
maximum output
of
the test set.
For
other
combinations
of
input
and
output voltages, contact Megger.
::.+'~fl;~.!.;'"
7.,EIG::
H X W X
:~:~NS~O:~
X D
(em)
PQ~~3,~9(t~~fjeS.1000
454
46
X
46
X
28
in.
117 X 117 X
71
em
D().I(6aOQS~ri~S
1200 545
46
X 55 X 28
in.
117 X 140 X
71
em
OTHER
TECHNICAL SALES OFFICES
Norristown
U5A,
Toronto
CANADA,
Mumbai
INDIA,
Paris
FRANCE,
Sydney
AUSTRALIA,
Madrid
5PAIN
and
The
Kingdom
of
BAHRAIN.
ISO STATEMENT
Registered
to
ISO
9001:1994 Reg no. Q 09250
Registered
to
ISO
14001
Reg
no.
EMS
61597
DDA3000_6000_DS_en_ V11
www.megger.com
Megger
is
a
registered
trademark

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Megger DDA-1 and is the answer not in the manual?

Megger DDA-1 Specifications

General IconGeneral
BrandMegger
ModelDDA-1
CategoryTest Equipment
LanguageEnglish

Related product manuals