4. Technician settings (cont’)
-25 -
P43 – Soft start in heat – cut-in temperature
The fan will not start before the temperature
on T3 sensor reaches the cut-in temperature.
Range: 14...37°C / 57…99°F
Default: 36°C / 96°F
P44 – Soft start in heat – cut-out temperature
The fan will stop if the temperature on T3 sensor
drops below the cut-out temperature.
Range: 14...37°C / 54…95°F
Default: 32°C / 89°F
P46 – Cool differential band offset
Range: 0...5°C / 0…10°F
Default: 0°C / 0°F
P47 – Heat differential band (On/Off)
Range: 0...5°C / 0…10°F
Default: 1°C / 2°F
P48 – Heat differential band offset
Range: -5...0°C / -10…0°F
Default: 0°C / 0°F
P45 – Cool differential band (On/Off)
Range: 0...5°C / 0…10°F
Default: 1°C / 2°F