1
Call center for missing parts
1-855-242-6887
WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Read this instruction manual
thoroughly before installing or servicing this
equipment
WARNING:
1. Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
2. An LP tank not connected for use should not
be stored in the vicinity of this or any other
appliance.
DANGER:
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flames.
3. Open the lid.
4. If the odor continues, keep away from the
appliance and immediately call your gas
supplier or fire department.
WARNING: For Outdoor Use Only
WARNING:
This product can expose you to chemicals
including lead and Di (2-ethylhexyl) phthalate
(DEHP), which are known to the State of
California to cause cancer and birth defects or
other reproductive harm. For more information,
go to www.P65Warnings.ca.gov.
MODULAR SINK AND SIDE BURNER
MODEL #BG179CL
IMPORTANT DO NOT RETURN
Question, problems, missing parts? Don’t return the product to stores, please call our customer
service department at 1-855-CHANT-US (1-855-242-6887) from 8:00am to 5:00pm Eastern time,
Monday through Friday for assistance.
SUPPLIER STOCK#BG179A+C+D
3116505说明书BG179CL水台SAMS公司英文版
规格:280*213mm
材质:105g双铜纸 黑白印刷

Questions and Answers

  • D
    Dustin HernandezAug 13, 2025
    What to do if Member's Mark BG179A+C+D Grill won't light?
    • D
      David CooperAug 14, 2025
      If your Member's Mark grill or side cooker won't light, here are some things to check: * Ensure the ignition wire is connected to the electrical igniter/valve. Reconnect it if it's loose. * Adjust the distance between the ignition pin and the burner to be 5/32 in. - 3/16 in. for the side burner. * Make sure gas is supplied by turning on the regulator valve. * Check the battery and change the polarity or install a new AA battery if needed. * Ensure the electrode tip produces sparks at the burner port; reinstall the electrode if necessary. * Adjust the air shutter opening to a smaller size if it's too big.
  • R
    russelltorresAug 17, 2025
    What to do if my Member's Mark BG179A+C+D Grill has low heat with the knob in “HIGH” position?
    • R
      Roger JohnsonAug 17, 2025
      If you're experiencing low heat on your Member's Mark grill even when the knob is in the “HIGH” position: * For natural gas models, ensure your natural gas supply system has the correct gas pressure, as the model is set for 7 inches of natural gas usage. * Check for and clear any obstructions in the ports. * If using LP gas, refill the LP tank if it has run out.
  • A
    Andrew HartAug 21, 2025
    What to do if Member's Mark BG179A+C+D burner blows out?
    • L
      Luis GrantAug 21, 2025
      If your Member's Mark grill burner keeps blowing out, consider the following: * Refill the LP tank, as it might be empty. * Ensure the burner is correctly installed and aligned with the control valve. * Check the gas supply hose for leaks or knots, ensuring a sufficient gas supply.
  • M
    Martin RodriguezAug 25, 2025
    What to do for low heat on Member's Mark BG179A+C+D Grill using LP gas?
    • K
      Kristi MaldonadoAug 26, 2025
      Follow these instructions to address low heat with LP gas on your Member's Mark grill: 1. Ensure all burners are “OFF”. 2. Open the tank valve and wait 5 minutes. 3. Light the burner one at a time following the lighting instructions.
  • C
    Cheryl MoraAug 29, 2025
    What to do for low heat on Member's Mark BG179A+C+D Grill using natural gas?
    • V
      Victor PruittAug 29, 2025
      Check your gas line and make corrections by following the chart below, as gas pressure is significantly affected by the gas line and its length from the house gas line.
  • A
    Alicia SheltonSep 1, 2025
    Why is my Member's Mark BG179A+C+D Grill burner flame yellow and I smell gas?
    • E
      emilyjohnsonSep 1, 2025
      If your Member's Mark grill burner flame is yellow and you smell gas, it could be due to several reasons: * The air shutter opening might not be properly set. Adjust the opening to achieve blue flames (1/4 inch for LPG, 1/8 inch or less for NG). * Spiders or insects may have blocked the air shutter. Clean any blockages. * There might be gas leaks. Check for the source of any leaks.
  • M
    Monica BaldwinSep 5, 2025
    What causes excessive flare-up on a Member's Mark BG179A+C+D Grill?
    • C
      Christopher AndersonSep 5, 2025
      Excessive flare-ups on your Member's Mark grill can be caused by: * Grilling fatty meats. If this happens, move the meats to the warming rack until the flame settles down. * Using “HIGH” knob settings. Grill fatty meats with cold grids and knobs on the “LOW” setting. * Closing the hood when grilling. Keep the hood up when grilling.
  • A
    Andrew RobinsonSep 9, 2025
    Why won't the LED control panel lights light up on my Member's Mark BG179A+C+D Grill?
    • H
      howard66Sep 9, 2025
      If the LED control panel lights on your Member's Mark grill are not lighting up: * Check the power supply to ensure it's properly plugged in. * Inspect all wiring connections between the battery box and the LED, as well as the connections between the LEDs on the control panel, for damage or looseness. * Verify the wiring is attached to the control panel switch. * The switch might be defective and need replacement. * The LEDs themselves might be defective and need replacement.

Summary

Safety Warnings & Customer Support

General Safety Precautions

Critical warnings regarding installation, gas, fire hazards, and outdoor use.

Grill Operation Guide

Safety Information

Installation, Usage, and LP Tank Safety

Guidelines for installation, clearances, LP cylinder handling, and general usage rules.

Assembly Instructions

Natural Gas Conversion

Conversion Process, Safety, and Operation

Steps for converting to natural gas, including preparation, installation, and leak testing.

Operating Instructions

LP Gas Installation and Tank Handling

Detailed guide for connecting, operating, and disconnecting LP gas tanks safely.

Troubleshooting

Warranty Information

Member's Mark BG179A+C+D Specifications

General IconGeneral
BrandMember's Mark
ModelBG179A+C+D
CategoryGrill
LanguageEnglish

Related product manuals