COLD WEATHER OR EXTENDED STORAGE
126 eng
3. Place the O‑ring on the drain plug and apply Perfect Seal to
the threads. Install the drain plug in the module drain hole.
Tighten the drain plug to finger‑tight.
a - Gen 3 Cool Fuel Module
b - Drain plug
c - O‑ring
Tube Ref
No.
Description Where Used Part No.
19
Perfect Seal Drain plug threads 92-34227Q02
Battery Storage
Whenever the battery will be stored for an extended period of
time, be sure the cells are full of water and the battery is fully
charged and in good operating condition. It should be clean and
free of leaks. Follow the battery manufacturer's instructions for
storage.
Recommissioning the Power Package
1. Ensure that all cooling system hoses are connected properly
and hose clamps are tight.