DDC70/DDC80
4.4.4.3.Pressure Settings
Opening skate is the skate opening pressure value.
Keeping closed is the pressure value for the door to remain in the closed position.
Open acceleration is the pressure value for acceleration in the door opening zone.
Close acceleration is the pressure value for acceleration in the door closing zone.
Open maximum is the highest pressure value that will be reached during door opening.
Close maximum is the highest pressure value that will be reached during door closing.
Open deceleration is the pressure value for deceleration in the door opening zone.
Close deceleration is the pressure value for deceleration in the door closing zone.
Open slow is the pressure value at the moment of contact with the limit bumper in the door opening zone.
Close slow is the pressure value at the moment of contact with the limit bumper in the door closing zone.
Keeping open is the pressure value for the door to remain in open position.
When changing these parameters, the safety of the door should be considered as well as its performance.