MotorCycle Alarm
by
LEGOS1/LEGOS3
OPERATION MANUAL
SIGNALS
If various alarms have been triggered, the memory will signal them in a sequence with 3 second pauses and will repeat the sequence
every 6 seconds.
The memory is reset when the motorcycle is started up or when the alarm system is armed with the remote control again.
11
STATUS OF CENTRAL UNIT
LED DIRECTION INDICATORS SIREN
Passive arming Slow flashing 1 short flash 1 B
EEP
Arming by remote control Flashing 2 flashes 2 B
EEP
Arming without internal lift and tilt sensor (LEGOS 3)
On fixed during initial immunity phase
flashes 2 + 1 BEEP 2 + 1
Arming with open contact Flashing 2 flashes 2 BEEP-1 BOOP
Initial immunity phase Reversed flashing
Testing during the initial immunity phase Reversed flashing 1 B
EEP
Central unit armed Flashing
Alarm cycles Flashing lampeggianti Sounds
Disarming without alarms Switches off 1 flash 1 BEEP
Disarming when the motorcycle’s battery is flat Switches off 4 B
EEP
Disarming when alarms have been memorised Switches off briefly every 6 sec. 1 BEEP - 1 BOOP
MEMORISED ALARMS
LED SIGNALS
Internal movement sensor 1 flash
Contacts 2 flashes
Ignition sensing 3 flashes
EN
EN
Question and Answer IconNeed help?

Do you have a question about the Meta System LEGOS1 and is the answer not in the manual?

Summary

Passive Arming

Manual Arming

Arming Without Internal Movement Sensor

Arming the system without activating the internal movement sensor for LEGOS 3.

Disarming

System Phases

Initial Immunity Phase

The first 26 seconds after arming, allowing testing of protection functions.

Active Phase

The system is fully armed, and any alarm triggers will provoke a full alarm cycle.

Protection by the Alarm System

Carjacking Protection

Stop Mode & Emergency Functions

Stop Mode - Limiting Current Consumption

Automatic system shutdown to limit battery drain after prolonged inactivity.

Emergency Blinker

Arming or disarming the motorcycle's blinker using the remote control.

Panic Function

Panic (LEGOS 3)

Triggering a 10-second alarm cycle by pressing the second button on the remote.

Special Functions Configuration

Override Emergency Code

Override Emergency Code

Using a 5-digit emergency code to disarm the system if a remote control is lost or damaged.

Customising the Override Code

Remote Control Management

Restoring the Default Override Code

Procedure to restore the default '11111' override code using two remote controls.

Additional Remote Controls

Procedure for adding or removing remote controls from the alarm system's memory.

Meta System LEGOS1 Specifications

General IconGeneral
CategorySecurity System
TypeGPS Tracker
ConnectivityGSM/GPRS
GPS ReceiverYes
BatteryRechargeable Li-Ion
Operating Temperature-20°C to +60°C
Frequency Bands900/1800 MHz