OPERATING MANUAL
5.4 Changing the Filter
1. Remove the cover on the oil tank aer loosening and removing the screws.
2. Remove the old lter from its place inside the oil tank by turning in a clock wise direction.
3. Fix the new lter into its place by turning it in counter clock wise direction.
Note ! e suction lter element must be cleaned aer rst 200 hours of use, and then every 1000
working hours. Replace if damaged.