EasyManua.ls Logo

Meterman 38XR - Diode Test, Peak Hold, and Aux Features

Meterman 38XR
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
dBm
Ranges: -13 dBm to +50 dBm
Resolution: 0.01 dBm
Accuracy:
±0.7 dB + 8 dgts ( 45 Hz to 5 kHz )
±2.5 dB + 8 dgts ( 5 kHz to 10 kHz )
Reference impedance: 50
O
Input protection: 10 M
O
Overload protection: 1000 V dc or 750 V
ac rms
CONTINUITY
Audible indication: < 40
O
Response time: 100 ms
Overload protection:1000 V dc or 750 V
ac rms
DIODE TEST
Test current: 0.5 mA (approximate)
Accuracy: ±(1.5 % rdg + 5 dgts)
Resolution: 1 mV
Open circuit volts: 3.0 V dc typical
Overload protection: 1000 V dc or 750 V
ac rms
AUXILIARY FEATURES
h
or 10A Test Lead Connection: Beeps to
warn test leads are connected to measure
current, but the Function/Range Switch is
not set to measure current.
MIN MAX AVG: Displays the minimum,
maximum, or average value detected while
making a measurement.
HOLD: Holds the latest reading on the
display.
REL: Initiates relative measurements.
PEAK+/-: Record the peak+ or peak- value
in a measurement.
RANGE: Initiates manual range mode.
Backlight: Backlight auto-off approx. 60
seconds
Auto Power off: 30 minutes, typical
Shift (yellow button): Shift to dBm, ac, dc,
ac+dc, continuity, duty cycle, or RS232
REPLACEMENT PARTS
TL36 Test Lead Set with Alligator clips
FP500 mA fuse - Fuse Pack .5A/1000V (4
each)
FP100 10A fuse - Fuse Pack 10A/1000V
(2 each)
H2-XR Magne-Grip
®
Holster, clip, magnet,
and strap
XR-TA Input Adapter for K-type
thermocouple
TP255 K type thermocouple
38SW RS232 Accessory Kit
(PC software and cable)