5.1 Working range and pulse weighting data
Type
G
-Type
DN/Rp Connection type
Measuring range
operating volume flow
Qb [m
3
/h]
Measurin
g range
ratio
pe
max. gas
HF* [pulses/m
3
]
ext. pulse
HF* [pulses/m
3
]
int. pulse
NF* [pulses/m
3
]
int. pulse
Pressure
drop
[mbar]
Q
min
Q
max
MQMe
10
Rp 1“
Rp female thread
1,6
16
Rp 1“
4 bar
185.000195.000
15.08016.250
10
5
MQMe
16 Rp 1“ Rp female thread 2,5 25 Rp 1“ 4 bar 185.000195.000 15.08016.250 10 5
MQMe
25
Rp 1“
Rp female thread
4
40
Rp 1“
4 bar
185.000195.000
15.08016.250
10
5
MQMe
40 Rp 1“ Rp female thread 6,5 65 Rp 1“ 4 bar 185.000195.000 15.08016.250 10 5
MQMe
40
Rp 1½“
Rp female thread
6,5
65
Rp 1½“
4 bar
185.000195.000
15.08016.250
10
5
MQMe
10 DN25 Flange 1,6 16 DN25 16 bar 185.000195.000 15.08016.250 10 5
MQMe
16
DN25
Flange
2,5
25
DN25
16 bar
185.000195.000
15.08016.250
10
5
MQMe
25 DN25 Flange 4 40 DN25 16 bar 185.000195.000 15.08016.250 10 5
MQMe
40
DN25
Flange
6,5
65
DN25
16 bar
185.000195.000
15.08016.250
10
5
MQMe
40
DN50
Flange
6,5
65
DN50
16 bar
101.000107.000
8.4168.916
10
3
MQMe
65
DN50
Flange
5
100
DN50
16 bar
101.000107.000
8.4168.916
10
4
MQMe
100 DN80 Flange 8 160 DN80 16 bar 26.40027.200 1.8852.266 1 2
MQMe
160
DN80
Flange
12,5
250
DN80
16 bar
26.40027.200
1.8852.266
1
2
MQMe
250 DN80 Flange 20 400 DN80 16 bar 26.40027.200 1.8852.266 1 4
MQMe
160
DN100
Flange
12,5
250
DN100
16 bar
13.10013.900
935992
1
3
MQMe
250
DN100
Flange
20
400
DN100
16 bar
13.10013.900
935992
1
3
MQMe
400
DN100
Flange
32
650
DN100
16 bar
13.10013.900
935992
1
6
MQMe
400 DN150 Flange 32 650 DN150 16 bar 5.1005.400 318386 1 10
MQMe
650
DN150
Flange
50
1.000
DN150
16 bar
5.1005.400
318386
1
10
MQMe
1.000 DN150 Flange 80 1.600 DN150 16 bar 5.1005.400 318386 1 10
*