General safety warnings and precautions for using the instrument.
Information on instrument power sources, battery types, and charging procedures.
Details the controls, display, and indicators on the instrument's front.
Explains the instrument's display elements, indicators, and sound signals.
Describes how to configure various instrument settings and parameters.
Measures electrical parameters like voltage, frequency, and phase rotation.
Measures insulation resistance to ensure safety against electric shock.
Checks effectiveness of earth connections and equipotential bonding for safety.
Performs various tests to verify the functionality of Residual Current Devices (RCDs).
Measures contact voltage to ensure it's within safety limits.
Verifies the RCD's response time to residual currents.
Tests the RCD's threshold sensitivity to tripping current.
Conducts a comprehensive, automatic test sequence for RCD verification.
Measures line impedance and calculates short-circuit current and voltage drop.
Measures line impedance and calculates prospective short-circuit current.
Checks voltage drop under load conditions to ensure acceptable levels.
Measures earth resistance to ensure effective earthing protection.
Measures insulation resistance in PV installations for safety.
Tests the proper operation and efficiency of PV inverters.
Checks PV panel operation by comparing measured and nominal output values.
Tests DC side protection devices and calculates STC values.
Analyzes PV panel performance by measuring I/V characteristics.
Measures standard power parameters like P, Q, S, THDU, and PF.
Technical data and parameters for RCD testing.
Technical specifications for fault loop impedance and fault current calculations.
Specifications for fault loop impedance without a disconnect device.
Specifications for fault loop impedance when an RCD is selected.
Technical data for line impedance, short-circuit current, and voltage drop.
Technical specifications for earth resistance measurements.
Technical specifications for voltage, frequency, and phase rotation measurements.
Technical specifications for TRMS clamp current measurements.
Technical specifications for various power measurement functions.
Technical specifications for all PV system testing functions.
Safety warnings specific to the use of commanders.