Doc# 100576 • REV C (Sept 2017) Page 15 of 42
3.5.4.1 PROBE SERIES
All DPS units support Metrix MX2030, Metrix 10,000 series 7200 compable, Bently Nevada
3300, and Bently Nevada 7200 series probes. The DPS also supports one addional probe
type specied at the me of ordering.
3.5.4.2 PROBE DIAMETER
The DPS supports 5mm, 8mm and 11mm probe p diameters as part of its standard factory-
loaded curve set.
3.5.4.3 TARGET MATERIAL
DPS units support the standard four probe series listed in secon 3.5.4.1 calibrated for 4140
steel. The addional probe type specied at the me of ordering may be calibrated to a
variety of materials. Contact Metrix for informaon on special material calibraons.
3.5.4.4 MEASUREMENT
The Measurement eld is only acve for the MX2034 transmier model. The MX2034 sup-
ports three measurements: Radial Vibraon, Axial Posion, and Sha Speed (RPM).
3.5.4.4.1 RADIAL VIBRATION
The MX2034 performs a peak to peak detecon and drives the 4-20 mA output proporonal
to the congured range.
1) Select the new conguraon
parameters from the drop down list
2) Click the buon to send the new
conguraon to the DPS