SERVICE and REPLACEMENT PARTS (continued)
WIRING DIAGRAM
C5-CM2000 OR C5-CM1500 COMBO MODULE
19"
BLK
19"
WHT
27" WHT
10"BLK
16"
BLK
25"BLK
10"BLK
25"
BLK
34"
BLK
1360 OR 1950 W ELEMENT
E
E
19
19
Z
Z
8
A
2
8
20
3
23
22
MASTER
POWER
SWITCH
HEAT
THERMOSTAT
AMBER
LIGHT
THERMOMETER
TRANSFORMER
24
10
17
13
23
22
21
20
7
10
2
3
4
17
18
24
23
12
11
6
5
22
21
20
19
10
9
8
7
16
15
14
13
4
3
2
1
TERM BLOCK
Z
7
WHITE
BLACK
GREEN
GRN GROUND SCREW
POWER CORD 20A FOR C5-CM2000
15A FOR C5-CM1500
STRAIN RELIEF
13
1
AIR DUCT
THERMAL CUT-OUT
THERMOMETER SENSOR
HEAT THERMOSTAT BULB
BLOWER MOTOR
1
30"BLK
30" BLK
25" WHT
30"
BLK
8.50"
BLK
10"
BLK
16"
BLK
25"
BLK
19"BLK
10"
BLK
16"BLK
16" BLK
675 W ELEMENT
675 W ELEMENT
MOISTURE
THERMOSTAT
BULB
WATER PAN ENCLOSURE
MOISTURE
THERMOSTAT
AMBER
LIGHT
TOP OF MODULE
8
B
C
21
4
B
8
CONTROL PANEL
19
8
8
24
X
X
X
X
SELCTOR
SWITCH
E
D
C
17
17
E
B
B
B
A
120 volt