22
SERVICE and REPLACEMENT PARTS (continued)
WIRING DIAGRAM
C5-HM2000 OR C5-HM1500 HOLDING MODULE
STRAIN RELIEF
A
3
10
24
POWER CORD 20A FOR C5-HM2000
15A FOR C5-HM1500
GRN GROUND SCREW
GREEN
BLACK
WHITE
BLOWER MOTOR
HEAT THERMOSTAT BULB
THERMOMETER SENSOR
THERMAL CUT-OUT
1360 OR 1950 WATT ELEMENT
AIR DUCT
TERMINAL BLOCK
TRANSFORMER
THERMOMETER
AMBER
LIGHT
HEAT
THERMOSTAT
MASTER
POWER
SWITCH
TOP OF CONTROL PANEL
1
2
3
4
13
14
15
16
7
8
9
10
19
20
21
22
5
6
11
12
23
24
18
17
4
3
2
10
1
20
21
22
23
24
19
17
1
Z
2
19
17
20
Z
22
23
4
21
3
A
25"
BLACK
8.50"
BLACK
10"
BLACK
10"
BLACK
16"
BLACK
30"
BLACK
30"
BLACK
30"
BLACK
19"
BLACK
25"
BLACK
19"
WHITE
25"
WHITE
16"
BLACK
25"
BLACK
A
A
17
120 volt