23
SERVICE and REPLACEMENT PARTS (continued)
WIRING DIAGRAM
C5-PM1500 PROOFING MODULE
T2
20
3
23
22
MASTER
POWER
SWITCH
HEAT
THERMOSTAT
AMBER
LIGHT
THERMOMETER
TRANSFORMER
24
10
17
13
23
22
21
20
7
10
2
3
4
17
18
24
23
12
11
6
5
22
21
20
19
10
9
8
7
16
15
14
13
4
3
2
1
TERMINAL BLOCK
Z
7
WHITE
BLACK
GREEN
GRN GROUND SCREW
POWER CORD
STRAIN RELIEF
13
1
AIR DUCT
THERMAL CUT-OUT
THERMOMETER SENSOR
HEAT THERMOSTAT BULB
BLOWER MOTOR
1
8
10"
BLACK
30"
BLACK
30"
BLACK
27"
BLACK
19"
WHITE
25"
WHITE
30"
BLACK
8.50"
BLACK
10"
BLACK
16"
BLACK
25"
BLACK
19"
BLACK
10"
BLACK
16"
BLACK
16"
BLACK
16"
BLACK
25"
WHITE
17
A
2
A
A
27"
WHITE
9"
BLACK
675 W ELEMENT
675 W ELEMENT
MOISTURE THERMOSTAT BULB
WATER PAN ENCLOSURE
MOISTURE
THERMOSTAT
AMBER
LIGHT
TOP OF MODULE
8
8
T2
21
4
T2
T2
CONTROL PANEL
19
Z
19
120 volt