POSITIONERS
Series NP
Installation, Maintenance and
Operating Instructions
7 NP 72 en
Issue 5/02
Question and Answer IconNeed help?

Do you have a question about the metso automation neles NP729 and is the answer not in the manual?

metso automation neles NP729 Specifications

General IconGeneral
CategoryValve Positioners
BrandMetso Automation
ModelNeles NP729
Input signal4-20 mA
Enclosure ratingIP66
TypePneumatic
Supply pressure20-100 psi
Ambient temperature range-40 to +80°C (-40 to +176°F)
Hazardous area certificationsATEX, IECEx
CommunicationHART

Summary

Introduction to Positioners

Positioner Operating Principle

Explains the force balance principle behind the positioner's operation.

Technical Specifications

Lists key performance parameters and physical characteristics of the positioner.

Safety Precautions

Highlights critical safety warnings for operation and handling of the positioner.

Mounting on Metso Automation Actuators

Installing NP700/S1 on VDI/VDE 3845 Actuators

Step-by-step guide for mounting the NP700/S1 positioner on specific actuators.

Installing NP700/S2 on Series B Actuators

Instructions for mounting the NP700/S2 positioner on Metso Automation Series B actuators.

Piping Supply and Signal Air

Details on connecting air supply and signal lines to the positioner.

Input Signal and Directions of Operation

Preliminary Actions for the Adjustment

Basic Adjustment

Setting Closed Limit and Zero Adjustment

Procedure for setting the closed limit and performing zero adjustment.

Setting Open Limit and Range Adjustment

Procedure for setting the open limit and adjusting the range.

Alpha-Zero Adjustment

Split-Range Adjustment

Split-Range Adjustment Procedure

Details the process of performing split-range adjustments using the cam plate.

Maintenance

Pilot Valve Maintenance

Procedures for checking and cleaning the pilot valve.

Diaphragm Replacement

Step-by-step guide for replacing the positioner diaphragm.

Trouble Shooting

No Actuator Response to Signal

Identifies causes when signal pressure changes do not affect actuator position.

Actuator Reaches Final Position Prematurely

Troubleshooting for actuators reaching final position with small signal changes.

Inaccurate Positioning Issues

Common causes for inaccurate positioning of the positioner.

Overshooting or Slow Positioning

Diagnosing issues related to overshooting or slow response in positioning.

Ordering Spare Parts Information

Type Code Configuration