Slurry Pump
WH16AM1TAA0EN_02A.DOC JAN 04-W51
Care and maintenance
2/6
ITEM ACTION
RUNNING HOURS
10 100 250 1000
Water flushing gland seal. Check stuffing box connection for
leaks. Rectify as necessary.
×
Centrifugal Gland Seal Tighten gland follower screws or
renew seal as necessary.
×
Bearing Cylinder
Lubricate bearings. See section
9.4.
×
Check Bearings for overheating.
×
All fixings
Ensure attachments are secure.
Tighten to correct torque as
necessary.
×
Adjusting Screw Locknut (P38)
See Torque Table, Section 11.1.
×
Inspect Drive Belts, if fitted, for
deterioration and damage.
Replace as necessary. Check
drive belt tension and adjust as
necessary.
×
Check drive couplings, if fitted, for
security of connection.
×
Pump/Drive unit installation Check safety covers for security
of attachment - important
×
Check drive motor holding down
bolts for security of attachment.
×
Keep drive motor clean and free
from debris, slurry etc.
×
Service Drive Motor as
necessary.
In accordance with
manufacturer’s
instructions.
Pump impeller Check axial clearance after run-in
period. Adjust clearance by
shimming. Refer to Setting Pump
Clearances, sub-section 9.5.1.
After first 100
running hours and
repeat at intervals
equal to 25% of the
anticipated life of
the pump.