EasyManua.ls Logo

Mi-Fires Small Tinderbox Multifuel - Compliance; Technical Data

Mi-Fires Small Tinderbox Multifuel
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
1. COMPLIANCE
1.1 TECHNICAL DATA
This appliance designed for intermittent operation only.
SMALL TINDERBOX MULTIFUEL
Item No. 137SMFTBOX Mi-Fires Small Tinderbox MF (Multifuel)
Weight 59Kgs
Dimensions (WxDxH mm) 370 x 319 (max footprint/exc handle) x 548 (inc flue)
Flue size 125mm
MEDIUM TINDERBOX MULTIFUEL
Item No. 137MMFTBOX Mi-Fires Medium Tinderbox MF (Multifuel)
Weight 71Kgs
Dimensions (WxDxH mm) 420 x 334 (max footprint/exc handle) x 614 (inc flue)
Flue size 125mm
LARGE TINDERBOX MULTIFUEL
Item No. 137LMFTBOX Mi-Fires Large Tinderbox MF (Multifuel)
Weight 81Kgs
Dimensions (WxDxH mm) 490 x 343 (max footprint/exc handle) x 615 (inc flue)
Flue size 125mm
WOOD LOGS RESULTS
PARAMETER SMALL
TINDERBOX MF
MEDIUM
TINDERBOX MF
LARGE
TINDERBOX MF
Total efficiency 83.0% 82.5% 81.3%
Nominal heat output 5.0 kW 5.0 kW 5.0 kW
Mean CO emission (at 13 % O
2
) 0.09% 0.07% 0.11%
Mean flue gas temperature 290 ºC 272 ºC 274 ºC
Flue gas mass flow 3.1 g/s 3.4 g/s 3.8 g/s
Mean CnHm emission (at 13 % O
2
) 71 Nmg/m
3
43 Nmg/m
3
90 Nmg/m
3
Mean NOx emission (at 13 % O
2
) 89 Nmg/m
3
112 Nmg/m
3
97 Nmg/m
3
DIN Plus particulates (at 13 % O
2
) 12 Nmg/m
3
7 Nmg/m
3
10 Nmg/m
3
SMOKELESS MINERAL FUELS RESULTS
PARAMETER SMALL
TINDERBOX MF
MEDIUM
TINDERBOX MF
LARGE
TINDERBOX MF
Total efficiency 77.4 78.8% 77.0%
Nominal heat output 5.0 kW 5.0 kW 5.0 kW
Mean CO emission (at 13 % O
2
) 0.09% 0.06% 0.11%
Mean flue gas temperature 289 ºC 305 ºC 280 ºC
Flue gas mass flow 4.8 g/s 3.4 g/s 4.4 g/s
Mean CnHm emission (at 13 % O
2
) 34 Nmg/m
3
9 Nmg/m
3
17 Nmg/m
3
Mean NOx emission (at 13 % O
2
) 124 Nmg/m
3
123 Nmg/m
3
107 Nmg/m
3
DIN Plus particulates (at 13 % O
2
) 18 Nmg/m
3
13 Nmg/m
3
18 Nmg/m
3
Please note that details and specifications contained herein are correct at the time of going to print. We
reserve the right to change specifications at any time without prior notice.