DLS 2 with Aircraft GPS
For more control, advanced users can communicate with Altum by HTTP (Ethernet, Wi-Fi) or
serial (MAVLink) using the MicaSense APIs (Application Programming Interfaces). The APIs can
be used in lieu of the DLS 2 GPS to provide the sensor with a position and attitude data (from
the aircraft GPS, for example). Anytime GPS data is sent to the sensor via the API commands, it
will be written to the image metadata, overriding the DLS 2 internal GPS data for five seconds
(or until another update is sent via the API).
HTTP Connection
Attach a USB Ethernet adapter or USB Wi-Fi adapter to one of the USB 3 ports. See the User
Guide for MicaSense Sensors for connection details and information. For HTTP API details, visit
https://www.micasense.com/api
Serial Connection
Use the provided pigtail from the host connector cable to connect to your serial device. See
the Input and Output section of this document for pin layout and details. Visit
https://www.micasense.com/api to learn more about communicating with the MAVLink API.