Recommendations for Installation
The Altum should be installed such that it has a clear view of the area directly below the
aircraft. The “cone” of the lenses, especially thermal, which has the widest field of view (57º
HFOV), should be considered in the process of deciding where to mount the sensor on the
aircraft or payload bay.
Avoid putting windows or covers in front of the thermal sensor. Many materials that are
transparent in visible bands are opaque in LWIR (thermal), so any coverings may prevent data
collection. Even materials that are mostly transparent in LWIR will negatively affect the
radiometric accuracy of the sensor output.
The multispectral sensors feature a global shutter and can withstand some vibration without
degrading image quality; nevertheless, we recommend vibration isolation between the sensor
mounting platform and the aircraft.
Make sure the sensor points straight down (with respect to the earth) at all times during flight.
The best way to ensure this is to use a gimbal.
Airflow over all surfaces of the sensor is necessary for proper heat dissipation. Do not run Altum
on the bench or in the field for extended periods of time without airflow. Do not completely
cover or insulate the back surface of the sensor.
Normally, the sensor should be in landscape orientation. If you plan to mount the sensor in a
portrait orientation, remember to swap the vertical and horizontal parameters in your mission
planner.
Ensure that the sensor is completely protected during landing. Note that we do not
recommend using a lens cover during flight as it can filter the wavelengths that the sensor
measures. Instead, protect the sensor with a recessed installation or by using landing gear.
Use the provided lens cover when storing Altum, and do not set Altum lens-side-down as it will
rest on and scratch the lenses.
More integration guidelines for the DLS 2 are in the DLS 2 section of this guide.
© 2020 MicaSense, Inc

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MicaSense Altum and is the answer not in the manual?

MicaSense Altum Specifications

General IconGeneral
Sensor TypeMultispectral and Thermal
Capture Rate1 capture per second
Thermal Resolution160 x 120 pixels
Thermal Wavelength8-14 µm
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 60°C
Spectral BandsBlue, Green, Red, Red Edge, Thermal
Resolution160 x 120 (Thermal)
InterfaceEthernet, Serial, Trigger
Band Central WavelengthBlue: 475 nm, Green: 560 nm, Red: 668 nm, Red Edge: 717 nm
BandwidthBlue: 32 nm, Green: 27 nm, Red: 14 nm, Red Edge: 12 nm, NIR: 57 nm